//contact //product
DH-300L
Dahometer
1 set
4 days
Two years
T/T, Western Union,PayPal,Payoneer
Negotiable
Availability: | |
---|---|
Quantity: | |
300g Electronic High Precision Liquid Density Meter
Application:
Chemical solution, Food Industry, Aquaculture Industry, Mouth wash,Medicament, Research Laboratory.
Mobility liquid,vicious liquid,volatile liquid,corrosivity liquid,high temperature liquid,suspension liquid,emulsion and so on.
Alcohol, scaling powder, essence, blood, sodium chloride, glycerol, electrolyte, diesel,refrigerating, hydrofluoric acid, dichloromethane, vitriol.
Standards:In accordance with Archimedes principle, GB/T
611,GB/T11540,GB/T12206,GB/T5518 standards etc.
Combine Archimedes principle with modern electronics technique of
DH-300L; Digital display liquid densimeter; The data can be read directly
with high measuring accuracy; The operation is more easy and get
away from the influence of external factor and temperature compared
with traditional wechsler balance method and pycnometer method; It can be applied to the field of quality management, cost control,formula
researching and so on. Also,the solvent,adhesive,paint, pitch,resin,
chemical oils,edible oil,food additives,drink,dairy products can be
measured.
Specification:
Density resolution: 0.001 g/cm3
Maximum weight:300g
Minimum weight:0.005g
Measuring range: 0.001-99.999g/cm3
Features:
(1)Density value can be showed by one procedure;repeatedly
continuous rapid measurement can be worked.
(2)Digital display; High accuracy of measurement; Simple operation;
Stable and Durable.
(3)Density value of samples with the temperature from normal to
100 centigrade can be measured.
(4)Take samples conveniently;50CC or less would be okay.
(5)There is no cumbersome debugging and operation compared with
traditional wechsler balance method and pycnometer method.
(6)It is very easy to clean measurement cup; can’t get the limitation of the size of pycnometer caliber.
(7)Coordinate with the operation of thermostatic tank to measure the proportion with the required temperature.
(8)Adopt the completed special windproof and dustproof cover,which makes the structure convenient and durable.
(9)Volatile liquid,corrosivity liquid,vicidity liquid,strong acid and strong lye liquid can be measured quickly.
(10)Interface of RS-232C is included.the printer of DE-40 will be available to connect PC and the instrument.
Measurement procedure:
(1)Place beaker with sample on testing board. and take off weight of pothook.
(2)Hang standard weight on the pothook and submerged into liquid to be tested totally; press ENTER key to memory. Density value will be displayed.
Standard accessories:
Host,measurement frame,DE-20A standard liquid measurement
assembly,tweezer,thermometer,100G weight,windproof and dustproof
cover,measurement support,power transformer
DE-20A standard liquid measurement assembly:
Two stainless steel pothooks,one normal glass weight,one normal
stainless steel weight,two beakers.
Optional accessories:
DE-40 printer,DE-20B anti corrosive liquid measurement assembly.
Instruction Table:
Name/model | DH-300L Electronical Liquid Densimeter |
Brand | DAHOMETER |
Density resolution | 0.001 g/cm3 |
Density range | 0.001—99.999g/cm3 |
Measurement type | a:mobility liquid,viscous liquid,volatile liquid,corrosivity liquid,high temperature liquid,suspension liquid,emulsion and so on
b:alcohol,scaling powder,essence,blood,sodium chloride,glycerol, electrolyte,diesel,refrigerating, hydrofluoric acid,dichloromethane,vitriol |
Measurement Principle | Archimedes principle displacement method |
Measurement mode | 1 group |
Measurement time | About 5 seconds |
Memory mode | memory in shorter time by one procedure |
Result disply | Density value |
Specific Gravity Measurement frame | stainless steel specific gravity measurement frame |
Function of setting | Temperature setting,solution density setting,measurement weights setting of weight in the normal liquid and water |
Calibration mode | auto correction with one button,auto detection. |
Measurement testing | distilled testing |
Output mode | standard interface of RS-232,output and print testing data conveniently |
Standard accessories | Host,measurement frame,DE-20A standard liquid measurement assembly,tweezer,thermometer,100G weight,wind and dust cover,measurement support,power transformer
DE-20A standard liquid measurement assembly: Two stainless steel pothooks,one normal glass weight,one normal stainless steel weight,two beakers. |
Optional accessories | DE-40 printer,DE-20B anti corrosive liquid measurement assembly |
power | AC~220V / 50HZ0. |
Main feature | data display,accuracy,rapid,convenience durable,economy |
300g Electronic High Precision Liquid Density Meter
Application:
Chemical solution, Food Industry, Aquaculture Industry, Mouth wash,Medicament, Research Laboratory.
Mobility liquid,vicious liquid,volatile liquid,corrosivity liquid,high temperature liquid,suspension liquid,emulsion and so on.
Alcohol, scaling powder, essence, blood, sodium chloride, glycerol, electrolyte, diesel,refrigerating, hydrofluoric acid, dichloromethane, vitriol.
Standards:In accordance with Archimedes principle, GB/T
611,GB/T11540,GB/T12206,GB/T5518 standards etc.
Combine Archimedes principle with modern electronics technique of
DH-300L; Digital display liquid densimeter; The data can be read directly
with high measuring accuracy; The operation is more easy and get
away from the influence of external factor and temperature compared
with traditional wechsler balance method and pycnometer method; It can be applied to the field of quality management, cost control,formula
researching and so on. Also,the solvent,adhesive,paint, pitch,resin,
chemical oils,edible oil,food additives,drink,dairy products can be
measured.
Specification:
Density resolution: 0.001 g/cm3
Maximum weight:300g
Minimum weight:0.005g
Measuring range: 0.001-99.999g/cm3
Features:
(1)Density value can be showed by one procedure;repeatedly
continuous rapid measurement can be worked.
(2)Digital display; High accuracy of measurement; Simple operation;
Stable and Durable.
(3)Density value of samples with the temperature from normal to
100 centigrade can be measured.
(4)Take samples conveniently;50CC or less would be okay.
(5)There is no cumbersome debugging and operation compared with
traditional wechsler balance method and pycnometer method.
(6)It is very easy to clean measurement cup; can’t get the limitation of the size of pycnometer caliber.
(7)Coordinate with the operation of thermostatic tank to measure the proportion with the required temperature.
(8)Adopt the completed special windproof and dustproof cover,which makes the structure convenient and durable.
(9)Volatile liquid,corrosivity liquid,vicidity liquid,strong acid and strong lye liquid can be measured quickly.
(10)Interface of RS-232C is included.the printer of DE-40 will be available to connect PC and the instrument.
Measurement procedure:
(1)Place beaker with sample on testing board. and take off weight of pothook.
(2)Hang standard weight on the pothook and submerged into liquid to be tested totally; press ENTER key to memory. Density value will be displayed.
Standard accessories:
Host,measurement frame,DE-20A standard liquid measurement
assembly,tweezer,thermometer,100G weight,windproof and dustproof
cover,measurement support,power transformer
DE-20A standard liquid measurement assembly:
Two stainless steel pothooks,one normal glass weight,one normal
stainless steel weight,two beakers.
Optional accessories:
DE-40 printer,DE-20B anti corrosive liquid measurement assembly.
Instruction Table:
Name/model | DH-300L Electronical Liquid Densimeter |
Brand | DAHOMETER |
Density resolution | 0.001 g/cm3 |
Density range | 0.001—99.999g/cm3 |
Measurement type | a:mobility liquid,viscous liquid,volatile liquid,corrosivity liquid,high temperature liquid,suspension liquid,emulsion and so on
b:alcohol,scaling powder,essence,blood,sodium chloride,glycerol, electrolyte,diesel,refrigerating, hydrofluoric acid,dichloromethane,vitriol |
Measurement Principle | Archimedes principle displacement method |
Measurement mode | 1 group |
Measurement time | About 5 seconds |
Memory mode | memory in shorter time by one procedure |
Result disply | Density value |
Specific Gravity Measurement frame | stainless steel specific gravity measurement frame |
Function of setting | Temperature setting,solution density setting,measurement weights setting of weight in the normal liquid and water |
Calibration mode | auto correction with one button,auto detection. |
Measurement testing | distilled testing |
Output mode | standard interface of RS-232,output and print testing data conveniently |
Standard accessories | Host,measurement frame,DE-20A standard liquid measurement assembly,tweezer,thermometer,100G weight,wind and dust cover,measurement support,power transformer
DE-20A standard liquid measurement assembly: Two stainless steel pothooks,one normal glass weight,one normal stainless steel weight,two beakers. |
Optional accessories | DE-40 printer,DE-20B anti corrosive liquid measurement assembly |
power | AC~220V / 50HZ0. |
Main feature | data display,accuracy,rapid,convenience durable,economy |
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.