//contact //product
DY-100C
Dahometer
one set
5-7 days
1 years,Lifelong maintenance
TT/Western Union/Paypal etc
Negotiable
Availability: | |
---|---|
Quantity: | |
DY-100C Powder Tap Density Tester For Chmical Powder Materials Quality Test
Application:
The bulk density of a powder is expressed in terms of grams per mL by dividing the weight of a given "untapped" powder sample by its volume.
It is important to ensure that no settlement occurs during preparation such that the density of the powder concerned is "as poured" and therefore includes the contribution made by the volume of the interparticulate void. Tap Density, on the other hand, is the density attained after "tamping down". This is normally measured using an instrument that lifts and the drops a measuring cylinder or similar vessel containing the powder through a fixed distance. The Tap Density in grams per mL can now be calculated by dividing the sample weight by the final tapped volume.
Specification:
(1) Weight of testing object:<=500.00g
(2) Volume of testing object:<=250.00ml(standard accessory including
25ml,50ml,100ml,250ml measuring cylinder)
(3) Single vibration times:<=0-99999 times(the result will come out as bulk density when input zero times)
(4) Allowable motor force:0.86 N.m.
(5) Vibration frequency:maximum 300 round per minute(0-300 round per minute is adjustable,USA pharmacopeia standard is 300 round per minute)
(6) Vibration amplitude:maximum 15mm(1mm-15mm is adjustable,International standard is 3mm)
(7) Repeatability error:<=1%
(8) Accuracy error:<=1%
Features:
1.Drop Height-Easily Adjustment
The drop height is important for a tap density tester in order to meet different international standards.This tap density tester uses default 3mm height and some tapping washers in specific height to reach 14mm.They changes easily without opening the cover.
2.Working Panel-Intuitive
The intuitive LED and membrane working panel brings operator and easy and fast operation.Accurate to 4 decimals.Automatically saving all test information.Operator simply inputs the desired data and press start to test.
3.Rpm-Easily Adjustment
The rpm is also important for a tap density tester.This instrument uses a speed control to realize 250rpm and 300 rpm.The motor is default 300 rpm,just tun the knob and reach the right percentage to shift to 250rpm.
4.Analysis Result-Easily Printed
Integrated micro printer prints the test data after test including Sample No,weight,volume,tap number,tap density and operator.
5.Cover-Easily to Clean
The outer surface is plastic coated,it is strong and resistant to any powders non-corrosive or corrosive.It makes for the cleaning procedure as well as a longer working life.
DY-100C Powder Tap Density Tester For Chmical Powder Materials Quality Test
Application:
The bulk density of a powder is expressed in terms of grams per mL by dividing the weight of a given "untapped" powder sample by its volume.
It is important to ensure that no settlement occurs during preparation such that the density of the powder concerned is "as poured" and therefore includes the contribution made by the volume of the interparticulate void. Tap Density, on the other hand, is the density attained after "tamping down". This is normally measured using an instrument that lifts and the drops a measuring cylinder or similar vessel containing the powder through a fixed distance. The Tap Density in grams per mL can now be calculated by dividing the sample weight by the final tapped volume.
Specification:
(1) Weight of testing object:<=500.00g
(2) Volume of testing object:<=250.00ml(standard accessory including
25ml,50ml,100ml,250ml measuring cylinder)
(3) Single vibration times:<=0-99999 times(the result will come out as bulk density when input zero times)
(4) Allowable motor force:0.86 N.m.
(5) Vibration frequency:maximum 300 round per minute(0-300 round per minute is adjustable,USA pharmacopeia standard is 300 round per minute)
(6) Vibration amplitude:maximum 15mm(1mm-15mm is adjustable,International standard is 3mm)
(7) Repeatability error:<=1%
(8) Accuracy error:<=1%
Features:
1.Drop Height-Easily Adjustment
The drop height is important for a tap density tester in order to meet different international standards.This tap density tester uses default 3mm height and some tapping washers in specific height to reach 14mm.They changes easily without opening the cover.
2.Working Panel-Intuitive
The intuitive LED and membrane working panel brings operator and easy and fast operation.Accurate to 4 decimals.Automatically saving all test information.Operator simply inputs the desired data and press start to test.
3.Rpm-Easily Adjustment
The rpm is also important for a tap density tester.This instrument uses a speed control to realize 250rpm and 300 rpm.The motor is default 300 rpm,just tun the knob and reach the right percentage to shift to 250rpm.
4.Analysis Result-Easily Printed
Integrated micro printer prints the test data after test including Sample No,weight,volume,tap number,tap density and operator.
5.Cover-Easily to Clean
The outer surface is plastic coated,it is strong and resistant to any powders non-corrosive or corrosive.It makes for the cleaning procedure as well as a longer working life.
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.