//contact //product
You are here: Home » Products » Environmental Testing Chamber » Laboratory Cabinet Type UV Lamp Aging Test Chamber 220V/50Hz

Product Detail

Laboratory Cabinet Type UV Lamp Aging Test Chamber 220V/50Hz Laboratory Cabinet Type UV Lamp Aging Test Chamber 220V/50Hz

loading

Laboratory Cabinet Type UV Lamp Aging Test Chamber 220V/50Hz

Share to:
sharethis sharing button
Standards:ASTM G 154, ASTM D 4799 etc
Studio Size:W1140*H400*D500mm
Outside dimension:W1400×H450×D650mm
Testing time:0~999H, adjustable
  • DH-RUV-2

  • Dahometer

  • 1 set

  • 5-7 days

  • 1 years,Lifelong maintenance

  • TT/Western Union/Paypal etc

  • Negotiable

Availability:
Quantity:

Laboratory Cabinet Type UV Lamp Aging Test Chamber 220V/50Hz


Usage:

The material to be tested is placed in a cyclical program of alternating light and moisture at a certain temperature to accelerate the weathering test of the material to obtain the weather resistance of the material. The UV box can reproduce the hazards of outdoor months or years in days or weeks. Types of hazards include: fading, discoloration, loss of light, powdering, cracking, turbidity, air bubbles, embrittlement, strength, decay, and oxidation. This machine contains a shower device.


Features:

(1).The installation thickness is adjustable;Easy installation.

(2).Upward spinning door is not in the way of users to operate machine;The machine is only took very small space.

(3).By using special cooling system,the ordinary tap water is allowed to be used.

(4).Very convenient software program;Will automatically alarm if operate wrongly or machine breakdown;light intensity can be programmed.

(5).The lifetime of tube can be extended if has radiation calibrator.(more than 1600 hours)

(6).Can be divided into ordinary type,light irradiation controlling type,spraying

type.

 

Standards:

ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE, J2020, ISO 4892 All current UV aging test standards.

 

Light source:

The light source uses 8 imported UV fluorescent lamps with a rated power of 40W as the light source. Ultraviolet fluorescent tubes are distributed on both sides of the machine, 4 on each side. There are UVA-340 and UVB-313 light sources for users to choose from. The luminescence spectrum energy of the UVA-340 lamp is mainly concentrated at the wavelength of 340 nm, and the luminescence spectrum of the UVB-313 lamp is mainly concentrated near the wavelength of 313 nm. We use the UVA-340 lamp because the fluorescent light energy output will gradually decay with time. In order to reduce the impact of the test due to the attenuation of light energy, this test box is every 1/1 of all eight lamps. When the fluorescent lamp of 4 is used, an old lamp is replaced by a new lamp, so that the ultraviolet light source is always composed of a new lamp and an old lamp, thereby obtaining a constant output light energy. The effective life of the lamp can be around 1600 hours.

 

Power control:


1.Blackboard temperature and condensing temperature are controlled by controller.


2.The rest basically use imported electronic components.

Uniformity of irradiance: ≤ 4% (at the surface of the sample)

Blackboard temperature monitoring: The standard Pt-100 blackboard temperature sensor is used to precisely control the sample surface temperature during the test.

Blackboard temperature setting range: BPT 40-75 °C; but the actual maximum temperature limit of the internal temperature protection device is 93 °C ± 10%.

Blackboard temperature control accuracy: ±0.5 °C


3.Sink temperature monitoring: During the loop test, one test section is a dark condensation process, which requires a saturated water vapor that can generate a higher temperature in the tank. When the water vapor encounters a relatively cold surface of the sample, Dew will condense on the surface of the sample.

The sink is located in the lower part of the cabinet and has an electric heater.

Sink temperature control range: 40~60°C


4.The test box is equipped with a time controller, the range is 0~530H, power failure memory function.


5.Safety protection device:

Over temperature protection inside the box: When the temperature inside the box exceeds 93 °C ± 10%, the machine will automatically cut off the power supply of the lamp and heater, and enter the equilibrium state to cool.

The low water level alarm in the sink prevents the heater from being burned.

 

Specification:

Model

DH-RUV-2

Studio Size

W1140*H400*D500mm

Outside dimension

W1400×H450×D650mm

Temperature range

RT+10~70°C

Temperature uniformity

±2°C

Temperature fluctuation

±0.5°C

Wavelength ultraviolet light

UV-A: 315-400nm;  UV-B: 280-315nm (8pcs, 1600h lifetime)

Testing time

0~999H, adjustable

Materials

Inside and Outside SUS#304 stainless steel

Humidity range

≥90%RH

Lamp power

40W/Piece

Irradiance

1.0W/m2

Distance from sample to lamp

50±2mm (adjustable)

Power

220V/50Hz /±10% 4.5KW

3

Previous: 
Next: 

Related Products

About Us

Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.

Contact Us
​​​​​​​​​​​​​​ 
   Contact:Julie Zhong
   Tel:+86-0769-22403424
   Mobile/WhatsApp:+86 13267004347
  Email:sales03@hongtuo.com.cn
  Address:No. 2-1, Xinya Road, The Third Industrial Park, Dalingya Village, Daojiao Town, DongGuan, GuangDong, CN
Copyright  2021 Guangdong Hongtuo Instrument Technology Co.,Ltd Technology by www.leadong.com