Laboratory HDT / Vicat Softening Point Temperature Tester for Plastic And Rubber
Thermal deformation and Vicat softening point temperature tester is mainly used to measure the thermal deformation temperature or Vicat softening point of thermoplastic materials such as plastics and rubber after molding, and its temperature accuracy is the key to evaluating the performance of the instrument.
Specification:
1) Temperature control range: room temperature to 300 ° C;
2) Heating rate: 120 ° C / h, 50 ° C / h;
3) Maximum temperature error: ±0.5 °C;
4) Temperature measurement point: 1;
5) number of sample racks: 3;
6) Deformation measuring gauge: digital display dial gauge;
7) Deformation measurement range: 0 ~ 1.1mm;
8) Sample support span: 64mm, 100mm;
9) Maximum deformation measurement error: 0.01mm;
10) Heating medium: methyl silicone oil; (prepared by customers)
11) Cooling method: natural cooling above 150 °C, water cooling below 150 °C or natural cooling;
12) Instrument size: 810mm × 470mm × 780mm
13) Space required: 0.5m front and back, 1.5m left and right
14) Power: 2500VA 220VAC 50HZ
Configuration
1) 1 x Host
2) 3 x Sample holder
3) 3 x Hot deformation heads
4) 3 x Vicat pinion
5) 1 x Electric control box
6) 3 x Digital display dial gauge
8) 1 x Signal line
9) 1 x Screw screwdriver
10) 1 x Weight set
Name
Speci fication | A | B | C | D | E | F | G | H | I | T | W |
Weight(g) | 1000 | 900 | 500 | 200 | 100 | 50 | 20 | 10 | 5 | 2 | 60(Load bar) |
Pcs | 12 | 3 | 3 | 6 | 3 | 3 | 6 | 3 | 3 | 6 | 3 |
Remarks: Users need to have cooling water source and ventilation smoke exhaust equipment
Laboratory HDT / Vicat Softening Point Temperature Tester for Plastic And Rubber
Thermal deformation and Vicat softening point temperature tester is mainly used to measure the thermal deformation temperature or Vicat softening point of thermoplastic materials such as plastics and rubber after molding, and its temperature accuracy is the key to evaluating the performance of the instrument.
Specification:
1) Temperature control range: room temperature to 300 ° C;
2) Heating rate: 120 ° C / h, 50 ° C / h;
3) Maximum temperature error: ±0.5 °C;
4) Temperature measurement point: 1;
5) number of sample racks: 3;
6) Deformation measuring gauge: digital display dial gauge;
7) Deformation measurement range: 0 ~ 1.1mm;
8) Sample support span: 64mm, 100mm;
9) Maximum deformation measurement error: 0.01mm;
10) Heating medium: methyl silicone oil; (prepared by customers)
11) Cooling method: natural cooling above 150 °C, water cooling below 150 °C or natural cooling;
12) Instrument size: 810mm × 470mm × 780mm
13) Space required: 0.5m front and back, 1.5m left and right
14) Power: 2500VA 220VAC 50HZ
Configuration
1) 1 x Host
2) 3 x Sample holder
3) 3 x Hot deformation heads
4) 3 x Vicat pinion
5) 1 x Electric control box
6) 3 x Digital display dial gauge
8) 1 x Signal line
9) 1 x Screw screwdriver
10) 1 x Weight set
Name
Speci fication | A | B | C | D | E | F | G | H | I | T | W |
Weight(g) | 1000 | 900 | 500 | 200 | 100 | 50 | 20 | 10 | 5 | 2 | 60(Load bar) |
Pcs | 12 | 3 | 3 | 6 | 3 | 3 | 6 | 3 | 3 | 6 | 3 |
Remarks: Users need to have cooling water source and ventilation smoke exhaust equipment
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.