//contact //product
DH-MI-VP
Dahometer
1 set
5-7 days
1 years,Lifelong maintenance
TT/Western Union/Paypal etc
Negotiable
Availability: | |
---|---|
Quantity: | |
Manual MFI ASTM D1238 Melt Flow Index Tester for Plastic
Melt flow index (MFI), known as melt index, is a value that indicates the fluidity of plastic material during molding processing.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |
Manual MFI ASTM D1238 Melt Flow Index Tester for Plastic
Melt flow index (MFI), known as melt index, is a value that indicates the fluidity of plastic material during molding processing.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.