PP PC PE MFI Themoplastic Plastic Testing Equipment Extrusion Plastometer
It is used to determine the MFR value of the melt flow rate through the standard die every 10 minutes when various plastics and
gums pass through a certain temperature and load in a viscous flow state. It is suitble for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |
PP PC PE MFI Themoplastic Plastic Testing Equipment Extrusion Plastometer
It is used to determine the MFR value of the melt flow rate through the standard die every 10 minutes when various plastics and
gums pass through a certain temperature and load in a viscous flow state. It is suitble for melting high temperature polycarbonate, polysulfoxide, fluorine plastics, nylon and other engineering plastics. Also, it is appropriate for the polyformaldehyde, polystrene, polypropylene, ABS resin polyformaldehyde, polycarbonate resin and other low temperature plastic melting test. The machine is widely used in plastic production, plastic products, petrochemical and other industries as well as related universities, scientific research units and commodity inspection departments.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |