//contact //product
DH-OI-01
Dahometer
one set
a week
1 year
T/T, Visa,PayPal
Negotiable
Availability: | |
---|---|
Quantity: | |
Automatic Oxygen Index Apparatus AC220V 50Hz Oxygen/temp Index Tester
Feature:
1.Full color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and give a beep sound prompt, eliminating the trouble of manual adjustment of oxygen concentration;
2.The stepper proportional valve is adopted to improve the control accuracy of the flow rate. Closed loop control is adopted. The oxygen concentration drift program is automatically adjusted to the target value in the test, which avoids the disadvantages that the traditional oxygen index tester can not adjust the oxygen concentration in the test, and greatly improves the accuracy of the test.
Application:
It is suitable for the determination of the combustion properties of materials such as plastics,
rubber, fibers, foams, films and textiles, that is, the concentration percentage of the
lowest oxygen in which the polymer just maintains combustion.
Features:
◆ The combustion tube is made of high temperature resistant high quality quartz glass tube (inner diameter ¢85mm, length 300mm)
◆ Outlet diameter: φ40mm
◆ The mixer is filled with glass beads to mix oxygen and nitrogen evenly. (Bead φ4.5mm filling height 95mm, label one bag)
◆ Self-supporting sample holder, which can hold the sample vertically; (optional non-self-supporting type frame)
◆ Adopting relay control system, all electronic originals adopt domestic leading brands, which can better guarantee the performance and reliability of the machine.
◆ The equipment has the following safety protection devices: power supply overload, short circuit protection, and control loop overload protection.
Standards:
In line with GB/T 2406.2-2009, GB/T 2406.1-2008 standard
Applicable standards:
ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996
NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144-1992 ISO 15705-2002 ISO 4589-2-1996
Main Technical Parameter:
1. Adopt imported oxygen sensor, oxygen concentration can be digital displayed without calculation.the accuracy is higher and more accurate, the range is 0-100%
2. Digital resolution: ±0.1%
3. Measurement accuracy: 0.1 level
4. The touch screen setting program automatically adjusts the oxygen concentration
5. One-click calibration accuracy
6. One-click concentration ratio
7. Automatic alarm sound when the oxygen concentration is stable
8. With timing function
9. Can store experimental data
10. Can query historical data
11. Can clear historical data
12. Can choose whether to burn 50mm
13. Air source failure prompt
14. Oxygen sensor fault prompt
15. Prompt for wrong connection of oxygen and nitrogen
16. Oxygen sensor aging tips
17. Standard oxygen concentration input
18. The diameter of the combustion tube can be set (two common specifications are available)
19. Flow adjustment range: 0-20L/min (0-1200L/h)
20. Quartz glass tube: 75cm (can be customized according to user requirements)
21. Gas velocity in the combustion tube: 40mm±2mm/s
22. Overall dimensions: 650mm×400×830mm (can be customized according to user requirements)
23. Pressure gauge accuracy level 2.5, resolution: 0.01MPa
24. Test environment: ambient temperature: room temperature ~ 50 ℃;relative humidity: ≤70%;
25. Input pressure: 0.05-0.3MPa
26. Working pressure: nitrogen 0.15-0.20Mpa oxygen 0.15-0.20Mpa
27. The sample holder can be used for soft and hard plastics, various building materials, textiles, fire doors, etc.
28. Propane (butane) ignition system, the ignition nozzle is made of a metal tube, and the end has a nozzle with an inner diameter of Φ2±1mm, which can be bent freely. Can be inserted into the combustion tube to ignite the sample, flame length: 16±4mm, size 5mm-60mm can be adjusted freely,
29. Gas: Nitrogen and oxygen for industrial use, purity>99%; (user-provided/regular gas station industrial oxygen purity is generally between 99.2%-99.3%).
30. Power requirements: AC220 (+10%) V, 50HZ
31. Maximum power consumption: 150W
32. Self-supporting material sample clamp: can be fixed on the axis of the combustion cylinder and can clamp the sample vertically
33. Non-self-supporting material sample holder: can fix the two vertical sides of the sample to the frame at the same time (optional/applied to soft and non-self-supporting materials such as textiles)
Standard configuration:
1. Main unit (size: length * width * height 360mm * 250mm * 550mm) 1 set
2. Burning tube 1 set
3. Ignition 1 pcs
4. Power cord 1 pcs
5. Spare glass tube 1 pcs
6. Glass beads 1 bag (into the combustion column)
7. Nylon tube Ф 4 1.2 m (connecting the combustion column to the main unit)
8. Sealing ring some
9. Pointed sample holder 1 set
10. Metal mesh (into the combustion column) 1 pcs
11. Plastic air outlet plate 1 pcs
12. Rubber hose 2 pcs
13. M10×1 inner joint screw 1pcs (within the combustion column)
14. M10×1 joint nut 1 piece (connected to the main unit)
15. Instructions 1 copy
16. Non-self-supporting sample holder 1 set (optional)
Automatic Oxygen Index Apparatus AC220V 50Hz Oxygen/temp Index Tester
Feature:
1.Full color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and give a beep sound prompt, eliminating the trouble of manual adjustment of oxygen concentration;
2.The stepper proportional valve is adopted to improve the control accuracy of the flow rate. Closed loop control is adopted. The oxygen concentration drift program is automatically adjusted to the target value in the test, which avoids the disadvantages that the traditional oxygen index tester can not adjust the oxygen concentration in the test, and greatly improves the accuracy of the test.
Application:
It is suitable for the determination of the combustion properties of materials such as plastics,
rubber, fibers, foams, films and textiles, that is, the concentration percentage of the
lowest oxygen in which the polymer just maintains combustion.
Features:
◆ The combustion tube is made of high temperature resistant high quality quartz glass tube (inner diameter ¢85mm, length 300mm)
◆ Outlet diameter: φ40mm
◆ The mixer is filled with glass beads to mix oxygen and nitrogen evenly. (Bead φ4.5mm filling height 95mm, label one bag)
◆ Self-supporting sample holder, which can hold the sample vertically; (optional non-self-supporting type frame)
◆ Adopting relay control system, all electronic originals adopt domestic leading brands, which can better guarantee the performance and reliability of the machine.
◆ The equipment has the following safety protection devices: power supply overload, short circuit protection, and control loop overload protection.
Standards:
In line with GB/T 2406.2-2009, GB/T 2406.1-2008 standard
Applicable standards:
ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996
NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144-1992 ISO 15705-2002 ISO 4589-2-1996
Main Technical Parameter:
1. Adopt imported oxygen sensor, oxygen concentration can be digital displayed without calculation.the accuracy is higher and more accurate, the range is 0-100%
2. Digital resolution: ±0.1%
3. Measurement accuracy: 0.1 level
4. The touch screen setting program automatically adjusts the oxygen concentration
5. One-click calibration accuracy
6. One-click concentration ratio
7. Automatic alarm sound when the oxygen concentration is stable
8. With timing function
9. Can store experimental data
10. Can query historical data
11. Can clear historical data
12. Can choose whether to burn 50mm
13. Air source failure prompt
14. Oxygen sensor fault prompt
15. Prompt for wrong connection of oxygen and nitrogen
16. Oxygen sensor aging tips
17. Standard oxygen concentration input
18. The diameter of the combustion tube can be set (two common specifications are available)
19. Flow adjustment range: 0-20L/min (0-1200L/h)
20. Quartz glass tube: 75cm (can be customized according to user requirements)
21. Gas velocity in the combustion tube: 40mm±2mm/s
22. Overall dimensions: 650mm×400×830mm (can be customized according to user requirements)
23. Pressure gauge accuracy level 2.5, resolution: 0.01MPa
24. Test environment: ambient temperature: room temperature ~ 50 ℃;relative humidity: ≤70%;
25. Input pressure: 0.05-0.3MPa
26. Working pressure: nitrogen 0.15-0.20Mpa oxygen 0.15-0.20Mpa
27. The sample holder can be used for soft and hard plastics, various building materials, textiles, fire doors, etc.
28. Propane (butane) ignition system, the ignition nozzle is made of a metal tube, and the end has a nozzle with an inner diameter of Φ2±1mm, which can be bent freely. Can be inserted into the combustion tube to ignite the sample, flame length: 16±4mm, size 5mm-60mm can be adjusted freely,
29. Gas: Nitrogen and oxygen for industrial use, purity>99%; (user-provided/regular gas station industrial oxygen purity is generally between 99.2%-99.3%).
30. Power requirements: AC220 (+10%) V, 50HZ
31. Maximum power consumption: 150W
32. Self-supporting material sample clamp: can be fixed on the axis of the combustion cylinder and can clamp the sample vertically
33. Non-self-supporting material sample holder: can fix the two vertical sides of the sample to the frame at the same time (optional/applied to soft and non-self-supporting materials such as textiles)
Standard configuration:
1. Main unit (size: length * width * height 360mm * 250mm * 550mm) 1 set
2. Burning tube 1 set
3. Ignition 1 pcs
4. Power cord 1 pcs
5. Spare glass tube 1 pcs
6. Glass beads 1 bag (into the combustion column)
7. Nylon tube Ф 4 1.2 m (connecting the combustion column to the main unit)
8. Sealing ring some
9. Pointed sample holder 1 set
10. Metal mesh (into the combustion column) 1 pcs
11. Plastic air outlet plate 1 pcs
12. Rubber hose 2 pcs
13. M10×1 inner joint screw 1pcs (within the combustion column)
14. M10×1 joint nut 1 piece (connected to the main unit)
15. Instructions 1 copy
16. Non-self-supporting sample holder 1 set (optional)
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.