According to the standards:
The melt flow rate meter is suitable for the determination of the mass flow rate of thermoplastic melts specified in the national standard GB/T3682.1-2018 Determination of melt flow rate and melt volume flow rate of thermoplastics. It adopts the ISO 1133 regulations and meets the ASTM D1238 test standard. It complies with JB/T5456 "Melt Conditioner of Melt Flow Rate Meter" and JJG 878 - "Melt Flow Rate Meter" standard specification.
Main Technical Parameter:
Output port diameter: Φ2.095±0.005 mm, discharge port length: 8.000±0.025 mm (Optional: Φ1.050±0.005 mm, discharge port length: 4.000±0.025 mm)
Loading cylinder diameter: Φ9.550±0.007 mm, loading cylinder length: 152±0.100 mm
Piston head diameter: 9.475 ± 0.007 mm, piston head length: 6.350 ± 0.100 mm
|
|
Application industry:
Plastics industry; rubber industry; metrological quality inspection; colleges and universities; research institutes; commodity inspection and arbitration, technical supervision departments; petrochemicals; electrical appliances; composite materials;and other industries.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |
Plastic Raw Material Plastic Melt Flow Index Tester MFR
According to the standards:
The melt flow rate meter is suitable for the determination of the mass flow rate of thermoplastic melts specified in the national standard GB/T3682.1-2018 Determination of melt flow rate and melt volume flow rate of thermoplastics. It adopts the ISO 1133 regulations and meets the ASTM D1238 test standard. It complies with JB/T5456 "Melt Conditioner of Melt Flow Rate Meter" and JJG 878 - "Melt Flow Rate Meter" standard specification.
Main Technical Parameter:
Output port diameter: Φ2.095±0.005 mm, discharge port length: 8.000±0.025 mm (Optional: Φ1.050±0.005 mm, discharge port length: 4.000±0.025 mm)
Loading cylinder diameter: Φ9.550±0.007 mm, loading cylinder length: 152±0.100 mm
Piston head diameter: 9.475 ± 0.007 mm, piston head length: 6.350 ± 0.100 mm
|
|
Application industry:
Plastics industry; rubber industry; metrological quality inspection; colleges and universities; research institutes; commodity inspection and arbitration, technical supervision departments; petrochemicals; electrical appliances; composite materials;and other industries.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |