//contact //product
DH-XD-150
Dahometer
1 set
7 days
12 months
T/T, Western Union,PayPal,Payoneer...
Availability: | |
---|---|
Quantity: | |
Xenon Arc Lamp Acceleration Aging Test Machine UV Xenon Aging Test Chamber
1.Application:
Xenon arc test chamber reproduces the damage caused by full-spectrum sunlight and rain. In a few days or weeks, the Xenon arc tester can reproduce the damage that occurs over months or years outdoors.
2.Features:
1.Adopt the long axis fan motor,anti high and low temperature stainless steel multi-blades wheel,have good convection.and vertical diffusion cycle.
2.Double-layer anti-high temperature sealing strip has been used between the door and the box.to make sure the leakproofness for the testing area.
3.Adopt non-counteractive door knob,more easy operation.
4. Adopt high quality fixable PU running wheel of the bottom of machine.
5.Adopt multi-layer hollow tempered glass inspection window.(can observe the testing procedure clearly)
6.Irregular shape sample holder,make the installation of testing specimen more easier.and convenient to be used.
7. The working life of xenon lamp is determined by the radiation level.normal service life of lamp is 1600 hours.Lamp is easy to be changed.The effective filter can make sure spectrum demanded can be offered.
3.Specification:
Model | DH-XD | |||||
-80 | -150 | -225 | -408 | -800 | -1000 | |
Inner size: WHD(cm) | 40*50*40 | 50*60*50 | 60*75*50 | 60*85*80 | 100*100*80 | 100*100*100 |
External size: WHD(cm) | 105*185*115 | 105*185*115 | 115*195*115 | 135*210*120 | 155*230*145 | 155*230*165 |
Temperature and humidity uniformity | ± 2°C; ± 3%RH | |||||
Temperature range | 0℃~80℃, adjustable | |||||
Humidity range | 30%~98%R.H | |||||
Type of light source | imported air-cooled full solar spectrum long arc xenon lamp (average service life is around 1600 hours) | |||||
Rainfall time | 1~9999min, adjustable | |||||
Rainfall cycle | 1~240min,interval is adjustable | |||||
Wavelength | 290nm~800nm | |||||
Source irradiance | 290~800nm: 100~600w/m2 | |||||
Distance from the center of the arc to the sample holder | 350~380mm | |||||
Sample rotating basket speed | ≥1r/min | |||||
Water spray cycle | Water spray time: 0 ~ 99h59min, continuously adjustable; Stopping time: 0~99h59min, continuously adjustable | |||||
Light time | Continuous programming | |||||
Blackboard temperature | 85±3℃ | |||||
Cooling method | Mechanical refrigeration air cooling | |||||
Xenon lamp light | Xenon long-arc lamp, 1.8KW±10%, 290-800nm, 1200W/m2 | |||||
Xenon lamp light quantity | 1PCS | 2pcs | 3 PCS | |||
Box material | Stainless Steel SUS304# | |||||
Control and cooling system | Korea TEMI programmable controller | |||||
Power (w) | 4500 | 5500 | 6000 | 11800 | 13500 | 14000 |
weight (kg) | 230 | 230 | 300 | 450 | 550 | 680 |
Xenon Arc Lamp Acceleration Aging Test Machine UV Xenon Aging Test Chamber
1.Application:
Xenon arc test chamber reproduces the damage caused by full-spectrum sunlight and rain. In a few days or weeks, the Xenon arc tester can reproduce the damage that occurs over months or years outdoors.
2.Features:
1.Adopt the long axis fan motor,anti high and low temperature stainless steel multi-blades wheel,have good convection.and vertical diffusion cycle.
2.Double-layer anti-high temperature sealing strip has been used between the door and the box.to make sure the leakproofness for the testing area.
3.Adopt non-counteractive door knob,more easy operation.
4. Adopt high quality fixable PU running wheel of the bottom of machine.
5.Adopt multi-layer hollow tempered glass inspection window.(can observe the testing procedure clearly)
6.Irregular shape sample holder,make the installation of testing specimen more easier.and convenient to be used.
7. The working life of xenon lamp is determined by the radiation level.normal service life of lamp is 1600 hours.Lamp is easy to be changed.The effective filter can make sure spectrum demanded can be offered.
3.Specification:
Model | DH-XD | |||||
-80 | -150 | -225 | -408 | -800 | -1000 | |
Inner size: WHD(cm) | 40*50*40 | 50*60*50 | 60*75*50 | 60*85*80 | 100*100*80 | 100*100*100 |
External size: WHD(cm) | 105*185*115 | 105*185*115 | 115*195*115 | 135*210*120 | 155*230*145 | 155*230*165 |
Temperature and humidity uniformity | ± 2°C; ± 3%RH | |||||
Temperature range | 0℃~80℃, adjustable | |||||
Humidity range | 30%~98%R.H | |||||
Type of light source | imported air-cooled full solar spectrum long arc xenon lamp (average service life is around 1600 hours) | |||||
Rainfall time | 1~9999min, adjustable | |||||
Rainfall cycle | 1~240min,interval is adjustable | |||||
Wavelength | 290nm~800nm | |||||
Source irradiance | 290~800nm: 100~600w/m2 | |||||
Distance from the center of the arc to the sample holder | 350~380mm | |||||
Sample rotating basket speed | ≥1r/min | |||||
Water spray cycle | Water spray time: 0 ~ 99h59min, continuously adjustable; Stopping time: 0~99h59min, continuously adjustable | |||||
Light time | Continuous programming | |||||
Blackboard temperature | 85±3℃ | |||||
Cooling method | Mechanical refrigeration air cooling | |||||
Xenon lamp light | Xenon long-arc lamp, 1.8KW±10%, 290-800nm, 1200W/m2 | |||||
Xenon lamp light quantity | 1PCS | 2pcs | 3 PCS | |||
Box material | Stainless Steel SUS304# | |||||
Control and cooling system | Korea TEMI programmable controller | |||||
Power (w) | 4500 | 5500 | 6000 | 11800 | 13500 | 14000 |
weight (kg) | 230 | 230 | 300 | 450 | 550 | 680 |
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.