Electric Plastic Melt Flow Indexer Flow Index Extrusion Plastometer Tester
Introduction:
This series of melt indexer is specially designed for fast and accurate measurement. It has the characteristics of firm structure, easy operation, stable and reliable performance. It uses high-precision PID thermostat technology, high temperature control precision, nitriding of key parts, high strength and hardness. The thermal expansion deformation is small. DH-MI-BP,DH-MI-VP is a regular model, manual loading weight with automatic cutting function; DH-EI-BP,DH-EI-VP is the model with an electric loading weight with automatic cutting function.which means the weights is placed on the weight bracket in advance for electric loading and unloading, reducing manual operation. The DH-AI-VP is a fully automatic model with automatic loading weight and automatic cutting function, which automatically loads and unloads the corresponding weight according to the set mode.to further improve measurement efficiency.
Application industry:
Plastics industry; rubber industry; metrological quality inspection; colleges and universities; research institutes; commodity inspection and arbitration, technical supervision departments; petrochemicals; electrical appliances; composite materials;and other industries.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |
Electric Plastic Melt Flow Indexer Flow Index Extrusion Plastometer Tester
Introduction:
This series of melt indexer is specially designed for fast and accurate measurement. It has the characteristics of firm structure, easy operation, stable and reliable performance. It uses high-precision PID thermostat technology, high temperature control precision, nitriding of key parts, high strength and hardness. The thermal expansion deformation is small. DH-MI-BP,DH-MI-VP is a regular model, manual loading weight with automatic cutting function; DH-EI-BP,DH-EI-VP is the model with an electric loading weight with automatic cutting function.which means the weights is placed on the weight bracket in advance for electric loading and unloading, reducing manual operation. The DH-AI-VP is a fully automatic model with automatic loading weight and automatic cutting function, which automatically loads and unloads the corresponding weight according to the set mode.to further improve measurement efficiency.
Application industry:
Plastics industry; rubber industry; metrological quality inspection; colleges and universities; research institutes; commodity inspection and arbitration, technical supervision departments; petrochemicals; electrical appliances; composite materials;and other industries.
Description:
Brand | DahoMeter | ||||
Model | DH-MI-BP | DH-MI-VP | DH-EI-BP | DH-EI-VP | DH-AI-VP |
Weight loading method | Manual | Manual | electric | Electric | Automatic |
Testing result | Mass | Mass and volume | Mass | Mass and volume | Mass and volume |
MFR | MFR and MVR | MFR | MFR and MVR | MFR and MVR | |
Outlet diameter | Φ2.095±0.005mm,Outlet length:8.000±0.025mm | ||||
Loading cylinder diameter | Φ9.550±0.007mm,Loading cylinder length:152± 0.100mm | ||||
Piston head diameter | Φ9.475±0.007mm,Piston head length:6.350±0.100mm | ||||
Standard test load | A total of 8 full set of weights | ||||
Temperature control range | Room temperature~400℃(Optional~500℃) | Room temperature ~500℃ | |||
Temperature control resolution | 0.1℃ | 0.1℃ | 0.1℃ | ||
Constant temperature accuracy | 0.5℃ | 0.5℃ | 0.2℃ | ||
Displacement resolution | None | 0.001mm | 0.001mm | ||
Temperature control 4h drift | No less than ±0.5℃ | ||||
Cartridge temperature recovery time after feeding | ≤4min | ||||
Clock range | 0~6000s | ||||
Clock resolution | 0.1-1s | ||||
Countdown time setting | Freely set | ||||
Automatic cutting device | Set the interval time (any adjustable from 2 to 2000s) ,automatically complete the cutting | ||||
Jog cutting device | Manual button electric cutting | ||||
Manual cutting device | Manually rotating the handle to cut | ||||
Weight load accuracy | ≤±0.5% | ||||
Weight load range | 325-21600g discontinuous, combined load can meet standard requirements | ||||
Measuring range | 0.1~100g/10min | ||||
Power supply | AC220V / 50HZ or AC110V /60HZ; Choose different power supply voltages | ||||
Net weight | 48KG | ||||
Gross weight | 63KG |