High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic
High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic
High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic
High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic

loading

High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic

Share to:
sharethis sharing button
Standards:GB/T 1633、GB/T 1634、GB/T 8802、ISO 2507、ISO 75 etc
Temperature control range: room temperature to 300 ° C
Maximum temperature error: ±0.5°C
Number of test stands: 3
  • DH-300C

  • Dahometer

  • 1 set

  • 5-7 days

  • 12 months,Lifelong maintenance

  • T/T, Western Union,PayPal,Payoneer

  • Negotiable

Availability:
Quantity:

High Efficient Vicat Apparatus Automatic Vicat Apparatus For Plastic

Application:

It is mainly used for the determination of heat distortion temperature and Vicat softening point temperature of non-metallic materials such as plastic, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high strength thermosetting laminates. It is easy to operate and precise in control. It is a highly intelligent test instrument widely used in colleges and universities, research institutes and product quality supervision and inspection units.

It adopts PC control, displacement sensor to measure deformation, real-time curve drawing, and the test data is processed twice directly on the PC. The test data can be imported into the OFFICE software for editing and layout.

 

Standards:

GB/T 1633GB/T 1634GB/T 8802ISO 2507ISO 75ISO 306ASTMD 1525,ASTMD 648

 

Specification:

 

1) Temperature control range: room temperature to 300 ° C

2) Maximum temperature error: ±0.5°C

3) Heating rate: 50 ° C / h, 120 ° C / h

4) Temperature measurement point: 1

5) Deformation measurement range: -0.1mm~1.1mm

6) Maximum deformation error: ±0.01mm

7) Using medium: methyl silicone oil (customer-supplied);

8) Sample support span: 64mm, 100mm

9) Cooling method: natural cooling above 150 °C, water cooling below 150 °C or natural cooling;

10) Has an upper limit temperature protection function;

11) Number of test stands: 3

12) The control mode adopts the single-chip computer and PC distributed control system;

13) Instrument size: 880mm × 580mm × 1400mm

14) Space required: 1m before and after, 0.6m left and right

15) Power supply: 4500VA 220VAC 50HZ

 

Configuration:

 

1) 1 x Host

2) 3 x sample holders

3) 3x Hot deformation head

4) 3 x Vicat pinion

5) 1 x Brand desktop computer

6) 1 x Color inkjet printer

7) 1 x Power cord

8) 1 x Signal line

Remarks: Users need to have cooling water source and ventilation smoke exhaust equipment        

1


Previous: 
Next: 

Related Products

About Us

Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.

Contact Us
​​​​​​​​​​​​​​ 
   Contact:Julie Zhong
   Tel:+86-0769-22403424
   Mobile/WhatsApp:+86 13267004347
  Email:sales03@hongtuo.com.cn
  Address:No. 2-1, Xinya Road, The Third Industrial Park, Dalingya Village, Daojiao Town, DongGuan, GuangDong, CN
Copyright  2021 Guangdong Hongtuo Instrument Technology Co.,Ltd Technology by www.leadong.com