//contact //product
HT-1633CE
Dahometer
1 set
5-7 days
1 year
T/T, Western Union,PayPal,Payoneer...
Negotiable
Availability: | |
---|---|
Quantity: | |
Microcomputer Control And Intelligent Temperature Control Rapid Cooling Machine for HDT Vicat Tester
Introduction:
This product is developed and produced by Hongtuo Instrument. It adopts microcomputer control and intelligent temperature control. A certain amount of water is injected into the internal water tank of the machine, and the water is cooled by the refrigeration system. The chilled water is automatically injected into the copper tube of the thermal deformation and Vicat test oil tank, the chilled water takes away the heat, and then the high-temperature hot water flows into the water tank again for cooling, and the cooled chilled water is injected into the copper tube, thus cycle, so as to quickly achieve the cooling effect.
Application principle:
According to GBT1633 Vicat softening point temperature measurement standard and GTB1634 load deformation temperature measurement standard, the standard specifies four test methods for determining the Vicat softening temperature (VST) of thermoplastics.
The heating rate is generally 50°C/h or 120°C/h. For example, the heating process is 50°C/h, and it takes about 5.5 hours from room temperature to 300°C. To the starting temperature of the test, it takes more than 6 hours for natural cooling, about 5 hours for air cooling, and about 3.5 hours for circulating normal temperature water cooling + air cooling. It takes about 40 minutes to use circulating 6°C chilled water + air cooling.
Advantages:
l Fast cooling, it only takes 40 minutes to cool the test oil from 300°C to 23°C
l This machine can make the test oil cooling to 6℃,Meet the requirement of low initial temperature
l Imported refrigeration compressors are used to keep away from faults and have better mute effect
l Adopt Schneider contactor, with phase sequence protection, overload protection, more secure to use
l Emerson filters are used to efficiently filter impurities and avoid clogging
l Equipped with Chint air main switch to eliminate the hidden danger of electric leakage
l A variety of alarm prompts to avoid damage to equipment, accurate detection of equipment problems, eliminating the need for manual inspection
l The machine is easy to install and easy to use
Parameter:
Brand | Hongtuo | |||
Model | HT-1633CE-1 | HT-1633CE-2 | HT-1633CE-3 | |
Connect HDT vicat tester model | HT-1633-EL-3 HT-1633-EL-4 | HT-1633-EL-6 | HT-1633-EL-9 | |
Cooling capacity | Kca1/H | 2365 | 4541 | 7188 |
KW | 2.75 | 5.28 | 8.36 | |
Freezing medium | Name | R22 | R22 | R22 |
Control type | capillary tube | capillary tube | capillary tube | |
compressor | power(KW) | 0.75 | 1.5 | 2.2 |
condenser | Air Volume(m3/H) | 1000 | 2100 | 3200 |
Motor Power(KW) | 0.15 | 1.15 | 1.15*2 | |
Heat dissipation ambient temperature | ≤45℃ | |||
Evaporator | Chilled water volume(L/H) | 3600 | 3600 | 3600 |
Tank volume(L) | 40 | 40 | 60 | |
water pump | Pipe diameter(DN) | 6DN | 6DN | 25 |
Power(KW) | 0.37 | 0.37 | 0.37 | |
Lift(M) | 13 | 13 | 13 | |
System Description | Weight(KG) | 50 | 55 | 130 |
Overall dimensions(CM) | 85*52*80 | 85*52*80 | 115*60*110 | |
Fan(MM) | 350 fan 1 set | 350fan 2 sets | 350 fans 2sets | |
Power supply | 220V/50HZ | 220V/50HZ | 380V/50HZ | |
Total power | 1.32KW | 2.45KW | 3.15KW |
Product details:
Microcomputer Control And Intelligent Temperature Control Rapid Cooling Machine for HDT Vicat Tester
Introduction:
This product is developed and produced by Hongtuo Instrument. It adopts microcomputer control and intelligent temperature control. A certain amount of water is injected into the internal water tank of the machine, and the water is cooled by the refrigeration system. The chilled water is automatically injected into the copper tube of the thermal deformation and Vicat test oil tank, the chilled water takes away the heat, and then the high-temperature hot water flows into the water tank again for cooling, and the cooled chilled water is injected into the copper tube, thus cycle, so as to quickly achieve the cooling effect.
Application principle:
According to GBT1633 Vicat softening point temperature measurement standard and GTB1634 load deformation temperature measurement standard, the standard specifies four test methods for determining the Vicat softening temperature (VST) of thermoplastics.
The heating rate is generally 50°C/h or 120°C/h. For example, the heating process is 50°C/h, and it takes about 5.5 hours from room temperature to 300°C. To the starting temperature of the test, it takes more than 6 hours for natural cooling, about 5 hours for air cooling, and about 3.5 hours for circulating normal temperature water cooling + air cooling. It takes about 40 minutes to use circulating 6°C chilled water + air cooling.
Advantages:
l Fast cooling, it only takes 40 minutes to cool the test oil from 300°C to 23°C
l This machine can make the test oil cooling to 6℃,Meet the requirement of low initial temperature
l Imported refrigeration compressors are used to keep away from faults and have better mute effect
l Adopt Schneider contactor, with phase sequence protection, overload protection, more secure to use
l Emerson filters are used to efficiently filter impurities and avoid clogging
l Equipped with Chint air main switch to eliminate the hidden danger of electric leakage
l A variety of alarm prompts to avoid damage to equipment, accurate detection of equipment problems, eliminating the need for manual inspection
l The machine is easy to install and easy to use
Parameter:
Brand | Hongtuo | |||
Model | HT-1633CE-1 | HT-1633CE-2 | HT-1633CE-3 | |
Connect HDT vicat tester model | HT-1633-EL-3 HT-1633-EL-4 | HT-1633-EL-6 | HT-1633-EL-9 | |
Cooling capacity | Kca1/H | 2365 | 4541 | 7188 |
KW | 2.75 | 5.28 | 8.36 | |
Freezing medium | Name | R22 | R22 | R22 |
Control type | capillary tube | capillary tube | capillary tube | |
compressor | power(KW) | 0.75 | 1.5 | 2.2 |
condenser | Air Volume(m3/H) | 1000 | 2100 | 3200 |
Motor Power(KW) | 0.15 | 1.15 | 1.15*2 | |
Heat dissipation ambient temperature | ≤45℃ | |||
Evaporator | Chilled water volume(L/H) | 3600 | 3600 | 3600 |
Tank volume(L) | 40 | 40 | 60 | |
water pump | Pipe diameter(DN) | 6DN | 6DN | 25 |
Power(KW) | 0.37 | 0.37 | 0.37 | |
Lift(M) | 13 | 13 | 13 | |
System Description | Weight(KG) | 50 | 55 | 130 |
Overall dimensions(CM) | 85*52*80 | 85*52*80 | 115*60*110 | |
Fan(MM) | 350 fan 1 set | 350fan 2 sets | 350 fans 2sets | |
Power supply | 220V/50HZ | 220V/50HZ | 380V/50HZ | |
Total power | 1.32KW | 2.45KW | 3.15KW |
Product details:
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.