//contact //product
DH-300B
Dahometer
1 set
7 days
1 years,Lifelong maintenance
TT/Western Union/Paypal etc
Negotiable
Availability: | |
---|---|
Quantity: | |
Plastic Heating Deflection And Vicat Softening TemperatureTester Apparatus
Application:
HDT Vicat tester determining vicat softening and heat deflection temperature. Suitable for use in both laboratory layouts & industrial environments.
Standards:
GB/T1633 "Determination of vicat softening temperature (VST) of thermoplastics"
GB/T1634 "Determination of plastic load deflection temperature part 1: general test method"
GB/T8802 "Determination of softening temperature of plastic pipe fittings"
IS075-2013 "Determination of plastic load deformation temperature"
ASTM D 648 "Plastic heat deflection temperature test method"
ASTM D 1525 "Plastic vicat softening temperature test method"
Advantages:
1.Intelligent PID adjustment, accurate heating rate, precise temperature control
2.Can do thermal deformation test of various standard specimen
3.Can do Vicat softening point test of various standard specimen
4.The required load can be automatically calculated according to the test standard and sample size
5.Two heating rates can be selected, free switching, simple operation
6.When the test is completed or the temperature exceeds the upper limit, the temperature control will be turned off and shut down automatically
7.With software over-temperature protection and leakage protection
8.Has air-cooled and water-cooled dual rapid cooling
Specification:
1). Temperature control range: ambient temperature~300℃
2). Heating rate: (120±10)℃/h (12±1)℃/6min
(50±5)℃/h (5±0.5)℃/6min
3). Temperature indication error: 0.1℃
4). Temperature control accuracy: ±0.5℃
5). Maximum deformation indication error: ±0.001mm
6). Deformation measurement range: 0-10mm
7). Number of sample racks: 4
8). The weight of the load bar and the tray: 76g
9). Test span range: 64 or 100mm according to the standard
10). Fuel tank volume: about 13L
11). Heating medium: methyl silicone oil
12). Cooling method: built-in active air cooling or external water cooling
13). Heating power: 1.5kw
14). Appearance size: length 60cm*width 50cm*height 132cm
Configuration
1) 1x host
2) 4 x sample holders
3). 4 x heat deformation indenters
4). 4 x Vicat needles
5). 4 x sets of weights (including boxed weights) (attached table)
6). 1x power socket
Attached table: (accept non-standard customization)
The number of weights in one set, 4 sets in total:
Weights | Qty | Weights | Qty |
1g | 1 | 50g | 1 |
2g | 1 | 100g | 1 |
5g | 1 | 200g | 2 |
10g | 1 | 500g | 1 |
20g | 2 | 2000g | 2 |
Plastic Heating Deflection And Vicat Softening TemperatureTester Apparatus
Application:
HDT Vicat tester determining vicat softening and heat deflection temperature. Suitable for use in both laboratory layouts & industrial environments.
Standards:
GB/T1633 "Determination of vicat softening temperature (VST) of thermoplastics"
GB/T1634 "Determination of plastic load deflection temperature part 1: general test method"
GB/T8802 "Determination of softening temperature of plastic pipe fittings"
IS075-2013 "Determination of plastic load deformation temperature"
ASTM D 648 "Plastic heat deflection temperature test method"
ASTM D 1525 "Plastic vicat softening temperature test method"
Advantages:
1.Intelligent PID adjustment, accurate heating rate, precise temperature control
2.Can do thermal deformation test of various standard specimen
3.Can do Vicat softening point test of various standard specimen
4.The required load can be automatically calculated according to the test standard and sample size
5.Two heating rates can be selected, free switching, simple operation
6.When the test is completed or the temperature exceeds the upper limit, the temperature control will be turned off and shut down automatically
7.With software over-temperature protection and leakage protection
8.Has air-cooled and water-cooled dual rapid cooling
Specification:
1). Temperature control range: ambient temperature~300℃
2). Heating rate: (120±10)℃/h (12±1)℃/6min
(50±5)℃/h (5±0.5)℃/6min
3). Temperature indication error: 0.1℃
4). Temperature control accuracy: ±0.5℃
5). Maximum deformation indication error: ±0.001mm
6). Deformation measurement range: 0-10mm
7). Number of sample racks: 4
8). The weight of the load bar and the tray: 76g
9). Test span range: 64 or 100mm according to the standard
10). Fuel tank volume: about 13L
11). Heating medium: methyl silicone oil
12). Cooling method: built-in active air cooling or external water cooling
13). Heating power: 1.5kw
14). Appearance size: length 60cm*width 50cm*height 132cm
Configuration
1) 1x host
2) 4 x sample holders
3). 4 x heat deformation indenters
4). 4 x Vicat needles
5). 4 x sets of weights (including boxed weights) (attached table)
6). 1x power socket
Attached table: (accept non-standard customization)
The number of weights in one set, 4 sets in total:
Weights | Qty | Weights | Qty |
1g | 1 | 50g | 1 |
2g | 1 | 100g | 1 |
5g | 1 | 200g | 2 |
10g | 1 | 500g | 1 |
20g | 2 | 2000g | 2 |
Guangdong Hongtuo Instrument Technology Co.,Ltd has been specializing in density testing field on developing, innovating and producing since the year it was establised.